We have been deeply involved in the industry for more than ten years, and have served more than 10W+ customers. WiFi modules, Bluetooth modules, power modules and other products are in more than 80 countries and regions, providing customers with professional and reliable IoT module products.
Network digital IO acquisition control relay
HLK-DIO06 is a multi-interface network digital IO acquisition controller, with 6 digital inputs, 6 relay outputs, built-in wireless WiFi module, support RJ45 network port/RS232, and RS485 Modbus, quickly realize remote/local LAN/ Direct connection control, can realize inching/automatic/linkage control, and provide supporting PC control software and mobile APP software.
Product accuracy
Digital input signal acquisition frequency100Hz
Minimum switching time of relay output<10ms
Time accuracy (jog/delay/cycle)10ms
Time range (jog/delay/cycle)1-60000,10ms 10ms-10min
Clock error<5s/d
Timing accuracy1min
Timing rangeMonth:day:hour:minute Support monthly/weekly/daily/hour/minute
Timing typeTime point and time period
Product performance
Number of automatic control items6 items, each item can be turned on or off independently
Automatic control optionalTime point / time period / linkage Time point linkage / time period linkage
Number of output actionsClosing/opening/reversing/jogging, optional delay execution or cyclic execution
Indicator nameState description
PWRCommunication and equipment status indicator, on when there is communication data
LEDCommunication and equipment status indicator, on when there is communication data
Output status indicatorStatus indicator lights corresponding to the 6 digital outputs, which are on when the corresponding relay is closed, and off when the relay is disconnected
function buttonRestore factory settings button, press and hold for 6 to 10 seconds and then release
The PC software supports connecting the device through the serial port and the network, and the APP supports connecting the device through the network. For specific instructions, please refer to "User Manual-Configuration Tool & APP"
APP download can search "HLK-DIO16" in the application store, and multiple devices can be added at the same time.
(APP screenshot)
(PC screenshot)
Power supply | |
Input voltage | DC12V |
Power supply capacity | >500mA |
Digital input interface DI | |
Number of channels | 6 digital inputs |
Input type | Dry node and wet node |
Input voltage/current | Wet node maximum 12V, recommended 3.3V-5V Current 50mA (maximum) |
Form of protection | Full optocoupler isolation |
Relay output interface DO | |
Number of channels | 6 digital C-type relay output |
Output type | Each normally open/normally closed/input contact, all optocoupler isolation |
load capacity | 10A 277VAC/12A 125VAC |
Electrical life | 100,000 times |
Serial port & WiFi parameters | |
Interface form | UART/RS485 terminal |
Baud rate | 115200 |
agreement type | UART-HEX command protocol defined by our company RS485-Modbus RTU protocol |
Wireless parameters | 2.4GHz,150Mbps,802.11b/g/n |
Operating mode | AP/STA/AP+STA/Router/ |
Encryption type | WAP-PSK/WAP2-PSK、WPA/WPA2 |
Other parameters | |
working environment | -30℃-70℃,10-90%RH(No condensation) |
Storage environment | -30℃-80℃,5-95%RH(No condensation) |
Installation method | Screw hole/rail |
Dimensions | With shell: 145*90.2*21mm Without shell: 122*87*40.2mm |
weight | 211g |