We have been deeply involved in the industry for more than ten years, and have served more than 10W+ customers. WiFi modules, Bluetooth modules, power modules and other products are in more than 80 countries and regions, providing customers with professional and reliable IoT module products.
220V to 5V1A isolation switch power module 5M05 AC-DC AC to DC step-down stabilizer module
AC/DC-5W power module selection
MULTIPLE SPECIFICATIONS AVAILABLE
Universal input voltage 85-264VAC/70-350VDC
MODEL | POWER | VOLTAGE | ELECTRICITY |
HLK-5M03 | 5W | 3.3V | 1500mA |
HLK-5M05 | 5W | 5V | 1000mA |
HLK-5M09 | 5W | 9V | 556mA |
HLK-5M012 | 5W | 12V | 417mA |
HLK-5M015 | 5W | 15V | 333mA |
HLK-5M024 | 5W | 24V | 208mA |
*Same size and pin for the same series | |||
*Module dimensions 38x23x18mm(+8% error) |
Global universal input voltage 90~265VAC
Input/output isolation voltage 3000VAC
Low power consumption, green environment protection, no load <0.1 W
High efficiency, high power density
High reliability, long life design, continuous working time >0.1 million hours
Good output short circuit and over current protection and self - recovery
International standard pin, PCB board straight plug installation
Compliance with UL/CE/EMC and safety testing requirements
It can be used in medical treatment, industrial control, electric power, instrument and meter, communication, railway and other fields
Input characteristics (room temperature test)
rated input voltage100-240VAC
input voltage range85-264VAC/70-350VDC
Max Supply Current≤0.2A
Input Inrush Current≤10A(model)
Input slow start≤50mS
long term reliabilityMTBF≥100,000 H
External fuse recommended1a/250 vac or 10 Ω wire wound resistor
The input features
output loadload percentage 100%MAX
voltage regulation factor±0.2 %(Tpy)
load regulation±0.5 %(Tpy)
Output Current Limiting Threshold110%-150%(maximum load)
Output short circuit protectionSustainable, self-restoring (without damaging the host)
Ripple & amp; noise≤100mVp-p
*Ripple noise test: Rated input voltage, output full load. A 20MHz bandwidth oscilloscope with 10uF and 0.1UF capacitors at the load was used for the test。
Parameters are recommended
F1/fuse: 1 a/250 vac/10 Ω wire wound resistor, fuse
MOV1 Varistor: 10D561K(protect module from damage during surge)
C1/C2 safety capacitor: 0.1UF /275Vac(Filter/safety protection /EMC certification)
L1/Common Mode Choke: inductance value10-30mH(test requirement:1KHZ/0.3V 电流:100-500mA),EMI filter
note
1.Fuse and varistor are the basic protection circuit. 2. Safety capacitance and common mode inductance must not be omitted if certified。
Pin description
1: AC input; 3: -VO output negative; 4: +Vo output positive ;
* Note: If the pin definition of the power module is not in accordance with the selection manual, the label should prevail。
environmental conditions | |||
operating temperature | -25 ~ +60 | ℃ | |
storage temperature | -40~+80 | ℃ | |
relative humidity | 5-95 | % | |
heat-dissipating method | natural cooling | ||
atmospheric pressure | 80-106 | Kpa | |
altitude | ≤2000 | m | |
vibration | Oscillatory coefficients 10~500Hz,2G10min./1cycle,60min.each along X,Y,Z axes | Meet the requirements of secondary road transport | |
operating characteristic of electric apparatus | |||
ated input voltage | 90~245 | Vac | |
input voltage range | 85~264 | Vac | or 70~350Vdc |
Max Supply Current | ≤0.2 | A | |
Input Inrush Current | ≤10 | A | |
maximum input voltage | ≤270 | Vac | |
Input slow start | ≤50 | mS | |
Low input voltage efficiency | Vin=110Vac,The input load ≥69 | % | |
High input voltage efficiency | Vin=220Vac,The input load ≥70 | % | |
long term reliability | MTBF≥100,000 | h | |
External fuse recommended | 0.5A/250Vac | Slow-Blow | |
output characteristics | |||
no-loadratedoutputvoltage | 5.0±0.1 | Vdc | |
Full load rated output voltage | 5.0±0.2 | Vdc | |
Short time maximum output current | ≥1200 | mA | |
Long time maximum output current | ≥1000 | mA | |
voltage regulation factor | ±0.2 | % | |
load regulation | ±0.5 | % | |
Output ripple and noise | ≤50 | mV | |
On/off machine overshoot amplitude | (Rated input voltage, input plus 10% load)≤5 | %Vo | |
Output Current Limiting Threshold | Output 150-200% of maximum load | A | |
Output short circuit protection | Direct short circuit in normal input, after short circuit removal automatically return to normal work | Do not damage the machine |